Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10048990 RMB
Plant Area
>2000 square meters
  • Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
  • Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
  • Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
  • Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
  • Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
  • Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
Find Similar Products
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
K series
Cooling Capacity
1450 W@60Hz
Temperature Range
5-35°c
Temperature Stability
±0.1ºC
Max Flow
25 L
Max Pressure
1.7 Bar
Reservoir
8 L
Size of Connection
RP 1/2
Condition
New
Transport Package
Wooden Pallet
Specification
360 x475 x655 (mm)
Trademark
AUWII
Origin
China
HS Code
8418692090
Production Capacity
10000

Product Description

Product Parameters

Kingii K series chiller is special designed for small/medium-sized industrial equipment. The small size machines adopt front air come-in design, which is convenient for condenser cleaning,  and medium-size machines air discharge from the top, which is environmentally friendly and good for heat transfer. It is an ideal companion of small/medium industrial equipment refrigeration.

 

Vertical structure, beautiful appearance, small size with lockable caster wheels;
Removable front panel, easy to clean condenser;

Branded stainless steel pump;

Level display and level detector, easy to observe and monitored the level of liquid, and timely fluid supplement;

PP cotton and resin ion filter can be selected to ensure that the water is clean;

Various connectors, easy to connect with customer equipment;

Multiple types of remote control;

Multiple alarm protection functions: compressor delay protection, compressor over current protection, water flow alarm, high and low temperature alarm, etc.

Products Specifications
Type Model Temp. Stability (ºC) Temp. Range (ºC) Cooling Capacity (W@25ºC) Max Flow
(L/min)
Max Pressure (bar) Reservoir
(L)
Overall dimensions
WxDxH(mm)
Room Temp. high stability chiller K1s ±0.2 5-35 1200 25 1.7 8 360x475x655
K2s 1900 25 1.7 12 430x540x720
K3s 2600 40 2.5 20 500x605x812
K4s 3600 40 3.4 30 540x705x922
K5s 5600 60 3.6 50 540x880x972
K6s 8000 110 2.8 70 620x980x1072
K7s 10000 110 2.8 70 620x980x1072
K8s 15000 110 3.6 120 620x1260x1162
 
Low temp.
to - 20ºC High stability chiller
K1s-20 ±0.2 -20-35 900 15 1.7 8 360x475x655
K2s-20 1600 25 1.7 12 430x540x720
K3s-20 2200 40 2.5 20 500x605x812
K4s-20 3200 40 3.4 30 540x705x922
K5s-20 5200 40 3.4 50 540x880x972
K6s-20 7200 110 2.8 70 620x980x1072
K7s-20 8000 110 3.6 70 620x980x1072
K8s-20 12000 110 3.6 120 620x1260x1162
 
Low temp.
to - 40ºC High stability chiller
K5s-40 ±0.5 -40-35 3000 20 3.5 50 540x880x972
K6s-40 5000 25 3.5 70 620x980x1072
K7s-40 6000 25 3.5 70 620x980x1072
K8s-40 8000 55 4.5 120 620x1260x1162
Room temp. on/off chiller K1r ±1 5-35 1200 25 1.7 8 360x475x655
K2r 1900 25 1.7 12 430x540x720
K3r 2600 40 2.5 20 500x605x812
K4r 3600 40 3.4 30 540x705x922
K5r 5600 60 3.6 50 540x880x972
K6r 8000 110 2.8 70 620x980x1072
K7r 10000 110 2.8 70 620x980x1072
K8r 15000 110 3.6 120 620x1260x1162
 
High stability dual temp.
chiller
K2t ±0.2 5-35 1600 5 4.5 18 430x540x720
K3t 2400 20 3.5 24 500x605x812
K4t 3200 25 3.5 40 540x705x922
K5t 5200 40 3.4 55 540x880x972
K6t 7200 40 5 75 620x980x1072
K7t 10000 40 5 75 620x980x1072
K8t 15000 110 3.6 128 620x1260x1162
 
Room temp. pure water type high stability chiller K1p ±0.2 5-35 1200 25 1.7 12 360x475x655
K2p 1900 25 1.7 22 430x540x720
K3p 2600 40 2.5 30 500x605x812
K4p 3600 40 3.4 50 540x705x922
K5p 5600 40 3.4 50 540x880x972
K6p 8000 40 3.4 70 620x980x1072
K7p 10000 110 2.8 70 620x980x1072
K8p 15000 110 2.8 120 620x1260x1162

Famous Brand for Main Components 

Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption ChillerIndustrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption ChillerIndustrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption ChillerIndustrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption ChillerIndustrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption ChillerIndustrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption ChillerIndustrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller
After-sales Service
1) One Year guarantee for accessories except the consumable parts,Life long service with charge; 
2) Favorable price for spare parts and accessories in future; 
After sales service, once any problem with our product, we will try to solve the problem by email or Tel Promptly, if can not solve, we will try other method till problem shooting down. 
Training 
1) Cost free training within the warranty period of the product clients have purchased among equipment being installation, setup and commissioning by emails and phones; 
2) Cost free for training and lunch in our company. But travel expenses should be cover by clients. 
3) Practical training on a fee paid basis according to individual programs and customized equipment.

Industrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption ChillerIndustrial Water Cooling Chiller Ammonia Absorption Liquid Nitrogen Air Cooled Water Absorption Chiller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier